Wichita Pole Barn Builders handles pole barn concrete slab installation in the South Central Kansas area. We can complete this as part of a new building project, so the floor, the posts and the doors are planned together instead of by three different crews. We have more than 25 years in metal building construction, so we're often asked to pour concrete slabs. And we've done this for simple post-frame to massive 80,000 square foot commercial buildings.
Soil matters more than the mix. Parts of Sedgwick County sit on Irwin silty clay loams, which shrink and swell with moisture, while the river bottoms are sandy with a high water table. A 4-inch slab suits cars and light storage, while 6 inches is what we pour under trucks and equipment. Call your local experts in the Wichita area today!
Call 316-688-2046 Now โTell us about your project. We'll call you back fast.
We'll respond same-week. Need to talk now? Call 316-688-2046.
A concrete slab inside a pole barn is a separate structural decision from the post foundation, and treating them as one and the same is a common mistake.
We compaction-test the sub-grade to 95 percent Standard Proctor density before forming, rather than visually grading it and assuming it's ready. This is the detail that most affects whether a slab cracks or settles unevenly.
Site excavation and base prep, clearing, grading, and 6 inches of crushed stone, is quoted separately from the slab itself, and on a sloped or soft pad it is the larger of the two.
A slab is quoted off the ground it is going on, so we will not hand you a number before seeing the pad. What the floor has to carry sets thickness and reinforcement first: a shop floor with a service truck rolling across it gets rebar at 18 inch centers, where a dry storage floor may not need it. Next comes the sub-grade work, clearing, grading, crushed stone and compaction testing, then the vapor retarder, the 4,000 PSI mix, and sequencing the pour around post footings bored 4 feet deep under MABCD Form 116. A concrete number quoted sight unseen assumes the pad is already flat, firm and dry, so check that assumption. On a level lot that preparation is minor; on a sloped or soft one it reaches $2,000 to $25,000+ before a single form board is set. Tell us how the floor will be used for a range, and we price the slab and base work line by line after a site visit.
4,000 PSI concrete with micro-fiber mesh reinforcement is our standard, resisting early plastic shrinkage cracking better than plain concrete. Rebar at 18 inch centers is common for slabs supporting heavier equipment.
A 15-mil Stego Wrap vapor retarder installed beneath the slab manages ground moisture, especially important in areas with seasonal high water tables like the Equus Beds region.
The structural posts have their own footing requirement, independent of and deeper than the slab itself. Under MABCD Form 116, for a building inside that guide's limits, that means bored holes 4 feet deep in Wichita and unincorporated Sedgwick County, with the diameter scaled to how wide the building is.
We sequence the pour so the slab doesn't interfere with post footing depth and to reduce the risk of a cold joint that becomes a future crack line.
Kansas rain comes in bursts. Wichita has recorded as little as 12.15 inches in a year (1966) and as much as 53.82 inches (2008), with 10.31 inches falling on a single day in September 2008.
That swing works clay soil hard and pushes groundwater up under slabs. A polyethylene vapor retarder stops moisture coming through the floor; 15-mil products such as Stego Wrap exceed the ASTM E1745 Class A rating.
The city requires special approval for building permits in areas with a high groundwater table. The application must show the lowest floor elevation and whether pumping may be needed.
For habitable space in a dwelling, MABCD applies the Wichita Foundation, Basement and Slab-on-Grade Standards. A barndominium's living slab can be detailed differently from the shop slab beside it.
A slab is only as good as the specialty site work underneath it, which is easy to overlook once the concrete looks finished. Repair, concrete, insulation, site prep, and design work all carry their own technical standards, distinct from new-building framing.


Tell us how the floor will be used.
After a look at the site, we'll price the slab and base work line by line.
Call 316-688-2046 Now